| TM 11-5820-509-12
CHAPTER 3
OPERATION
WARNING
Before operating this equipment, make sure that all requirements of TB SIG 291 are satisfied. Injury or DEATH can result
from improper or careless operation.
Section I. CONTROLS AND INDICATORS
3-1. Control Panel
3-2. Description of Front Panel Controls,
All controls, indicators, and receptacles used by the
Indicators, and Receptacles .
operator are located on the front panel of Receiver-
Each panel-mounted control or indicator (fig. 3-1) is
Transmitter, Radio RT-671 /PRC-47. The front panel
listed in the following chart and a functional description is
controls and indicators are illustrated in figure 3-1 and
provided to assist the operator in the proper performance
described in detail in paragraph 3-2.
of his duties.
Figure 3-1. Receiver- Transmitter, Radio RT-671/PRC -7, front panel controls, indicators, and receptacles.
Control. indicator.
Control indicator,
or receptacle
Function
or receptacle
Function
ANTENNA
connector
Threaded fastener in bowl insulator to
deflection of this meter; when
which whip antenna, long-wire
BATTERY
antenna, or vehicular antenna lead-in
TEST pushbutton is pressed, and a
wire is individually attached.
power source is connected to the
XMTR OUTPUT meter
Performs two functions: during
radio set, indicates (white area)
tuning of the power amplifier,
whether input power is within
optimum adjustment of POWER
tolerance.
AMPLIFIER LOAD and POWER
POWER 20A DC fuse
A 20-ampere cartridge-type fuse that
AMPLIFIER TUNE controls results
protects the primary power source
in maximum needle
circuit when a dc input is connected
to the receiver-transmitter POWER
connector.
3-1
|