| TM 11-5820-509-12
Control. indicator.
or receptacle
Function
Control. indicator,
Sw pos
Function
POWER 5A AC fuse .................... A 5-ampere cartridge-type fuse that
or receptacle
ON /OFF
Power on and
protects the primary power source
lights off.
circuit when an ac input is connected
ON /LO
Power on and
to the receiver-transmitter POW E R
lights low
connector.
ON /HI
Power on and
KILOCYCLES indicator
A digital display that indicates the
lights high
operating frequency to which the
AUDIO connectors ....................... Parallel-connected
for
Receiver-transmitter is tuned.
connecting voice and telegraph
BATTERY TEST push-
input/output devices. When either
button........................................ Can be used for two applications: during
connector is not used, install connector
power source checking, pressing the
protector.
pushbutton allows the operator to
VOLUME control ......................... During receive mode, controls received
determine if the input power source is
audio output level; during transmit
within limits (white area on XMTR
mode, controls sidetone level in
OUTPUT meter); during emergency
input/output device.
operation, pressing the pushbutton
POWER AMPLIFIER
Matches power amplifier output
allows the operator to bypass an
TUNE control.
overtemperature relay to allow
adjustment) as monitored on XMTR
transmission continuation.
OUTPUT meter during power
CW-FSK/VOICE
Controls high voltage power
amplifier tuning.
switch (2-position
supply for transmission
POWER AMPLIFIER
Matches power amplifier output
toggle.
Sw pos
Function
LOAD control
CW-FSK
Directly
ener-
adjustment) as monitored on XMTR
gizes the high
OUTPUT meter during power
voltage supply
amplifier tuning.
VOICE
The high voltage
LOCK knob .................................. Locks the turns counters of POWER
supply
is
AMPLIFIER TUNE and POWER
enabled
by
AMPLIFIER LOAD controls to
other switches.
prevent them from moving from their
Grounding terminals .......................... Used as grounding points for
optimum settings.
the ground-plane radials
XMTR PWR switch (3-
Controls power amplifier output:
POWER connector........................ Receptacle for connecting the power
position rotary).
Sw pos
Function
input source to the receiver-
LO
Selects reduced
transmitter. Accommodates both ac
power output.
and dc power cables
OFF
Disconnects
Frequency control knobs ............... Selects operating frequency as displayed
power
on KILOCYCLES indicator
amplifier from
Control
Function
high
voltage
Left knob
Selects
the
power supply
thousands
HI
Selects maximum
digit indicator.
power output.
Center knob
Selects
the
M ADJ control ............................. When rotated clockwise during power
hundreds and
amplifier tuning only, increases
tens
digit
sensitivity of XMTR OUTPUT meter.
indicator.
OPR-TUNE switch (2
Controls high-voltage power
Right knob
Selects the units
position toggle)
supply:
digit indicator.
Sw pos
Function
POWER/LIGHTS
Controls power and lights on/off
OPR
During radio
switch(4-position
functions:
set operation,
rotary).
Sw pos
Function
the high
OFF/OFF
Power off and
voltage supply
lights off.
is enabled by
other switches.
3-2
|