| TM 11-5820-477-30
NOTE
T h e information in table 2-4 applies to all models of the local control unit, exc
noted.
Table 2-4. Troubleshooting, Local Control Unit.
Malfunction
T e s t or Inspection
C o r r e c t i v e Action
1 . NO RINGER SIGNAL OUTPUT.
Step 1. Check magneto G101 for output voltage.
If output is inadequate, replace magneto (paragraph 2-9).
Step 2. Check capacitor C112.
I f defective, replace (paragraph 2-13).
3. Check audio line transformer T101 by checking winding resistance between terminals 5 and 6
Step
o f transformer (paragraph 2-5).
I f defective, replace (paragraph 2-13).
Step 4. Check for proper mechanical functioning and continuity of microswitch S103.
I f defective, replace (paragraph 2-13).
2 . BUZZER IS NOT ACTIVATED WHEN RINGER BUTTON ON REMOTE CONTROL UNIT
Step 1. Check capacitor C112.
I f defective, replace (paragraph 2-13).
Step 2. Check for proper mechanical functioning and continuity of microswitch S103.
I f defective, replace (paragraph 2-13).
3 . CALL LAMP DOES NOT LIGHT WHEN RINGER BUTTON ON REMOTE CONTROL UN
( A - , B- AND C- MODELS ONLY).
Step 1. Check for defective lamp.
I f defective, replace (paragraph 2-14).
Step 2. Check for defective call lamp control relay by checking relay windings out of the
Resistance between terminals 1 and 2 should be 5,000 ohms; resistance betwee
and 4 should be infinite.
I f defective, replace (paragraph 2-12).
2-15
|