Table 2-3. Troubleshooting, Remote Control Unit.
Malfunction
Test or Inspection
Corrective Action
1. NO RINGER SIGNAL OUTPUT.
Step 1. Check magneto G201 for output voltage.
If output is inadequate, replace magneto (paragraph 2-9).
Step 2. Check capacitor C214.
If defective, replace (paragraph 2-13).
Step 3. Check audio line transformer T201 by checking winding resistance between terminals 5 and
6 of transformer (paragraph 2-5).
If defective, replace (paragraph 2-13).
Step 4. Check for proper mechanical functioning and continuity of microswitch S203.
If defective, replace (paragraph 2-13).
2. BUZZER IS NOT ACTIVATED WHEN RINGER BUTTON ON LOCAL CONTROL UNIT IS PRESSED.
Step 1. Check capacitor C214.
If defective, replace (paragraph 2-13).
Step 2. Check for proper mechanical functioning and continuity of microswitch S203.
If defective, replace (paragraph 2-13).
3. CALL LAMP DOES NOT LIGHT WHEN RINGER BUTTON ON LOCAL CONTROL UNIT IS PRESSED
(A -, B- AND C- MODELS ONLY).
Step 1. Check for defective lamp.
If defective, replace (paragraph 2-14).
Step 2. Check for defective call lamp control relay by checking relay windings out of the circuit.
Resistance between terminals 1 and 2 should be 5,000 ohms; resistance between terminals 3
and 4, should be infinite.
If defective, replace (paragraph 2-12).
NOTE
In A-, B- and C- models, ringing signals are applied through an RF filter assembly.
Check the continuity of the RF filter (figures FO-2 through FO-4) if the call lamp or the
buzzer of either control unit is not activated.
Step 3. Check for defective buzzer DS201.
If defective, replace (paragraph 2-11).