| TM 11-5820-401-34-3/0967-LP-432-3060
5-20. SILICON VERSION IF DISCRIMINATOR A4200A ALINEMENT. (CONT)
1. Turn AN/URM-103 DEVIATION control clockwise until DEVIATION KHZ meter reads 8 kHz.
2. Set ME-30(*)/U to 1-volt scale.
3. Lift A4000 tray (1). (See test setup diagram
4. Connect ME-30(*)/U positive lead to TP4007 (2), and negative lead to ground.
5. Adjust L4202 (3) for maximum indication on ME-30(*)/U.
5-21. AUDIO AND SQUELCH PREAMPLIFIER A4300 ALINEMENT.
PURPOSE. This procedure adjusts the gain of the A4300 assembly.
TEST EQUIPMENT AND MATERIALS
Signal Generator AN/URM-103
Matching Unit CN-901/U
Frequency Counter AN/USM-207
T-Connector UG-274/U
Power Supply PP-1104(*)/G
Loudspeaker LS-454/U
Test Cable No. 1
Voltmeter ME-30(*)/U
TEST SETUP. Connect the equipment as shown in test setup diagram
. Remove R-442/VRC
bottom cover. (See paragraph 2-7.)
5-107
|