5-20. SILICON VERSION IF DISCRIMINATOR A4200A ALINEMENT. (CONT)
CONTROL AND SWITCH SETTINGS (CONT)
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
I POWER
AN/USM-207
TRACK
DISPLAY
MIN (fully counterclockwise)
PLUG IN
SENSITIVITY
FUNCTION
FREQ
104 (black knob)
GATE TIME
DIRECT/HETERODYNE
DIRECT
INPUT
0.3 V MAX (both switches to left)
100
FREQUENCY TUNING-MC
ALINEMENT PROCEDURE
NOTE
Check the frequency counter to make sure that the signal generator is outputting exactly
30 MHz. The rf level must be increased temporarily to enable the frequency counter to
display. Adjust the AN/URM-103 RF TUNING control as necessary, reset to 20-v rf
Ievel; then disconnect the T-connector from the counter.