| TM 11-5820-401-34-3/0967-LP-432-3060
SILICON VERSION IF DISCRIMINATOR A4200A ALINEMENT. (CONT)
5-20.
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
table. If using alternate equipment, inject 20-v rf at 30 MHz, 1-kHz modulation; 8-kHz deviation.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
ON-RESET
POWER
R-442/VRC
BAND
MC-TUNE-KC
30.00
Fully clockwise
VOLUME
NEW OFF
SQUELCH
OPERATE/OFF/STAND BY
OPERATE
AN/URM-103
FUNCTION
1000 Hz
o
A
BAND SWITCH
30.00
RF TUNING
DEVIATION RANGE KHZ
10
LO, 0-10 KUV
RF OUTPUT
Fully clockwise
DEVIATION
Adjust until needle on IF UV RF SET TO
RF SET TO LINE
LINE meter is over red line
20 v
LO RF UV
5-105
|