5-9. RECEIVER AUDIO RESPONSE TEST (X-MODE). (CONT)
2. Disconnect T-connector from AN/USM-207.
Audio Response Test (X-Mode) at 1 kHz
3. Set AN/USM-207 controls to the following positions:
POSITION/SETTING
CONTROL/SWITCH
I
TRACK
POWER
MIN (fully counterclockwise)
DISPLAY
0.1 v
SENSITIVITY
1 (black knob)
GATE TIME
FREQ
FUNCTION
4.
Disconnect rf cable from Adapter UG-514. (See test setup diagram
5.
Connect rf cable to AN/USM-207 FREQ A connector.
6.
Adjust AN/URM-127 FREQ RANGE DIAL for 1-kHz display on AN/USM-207.
7.
Disconnect rf cable from AN/USM-207 FREQ A connector.
8.
Reconnect rf cable to Adapter UG-514.
9.
Connect ME-30(*)/U INPUT lead A to Test Cable No. 1 terminal 2; connect lead B to
terminal A. Note meter indication.
STANDARD. ME-30(*)/U meter should indicate at least 0.78 volt.
10. If ME-30(*)/U meter does not indicate at least 0.78 volt, see troubleshooting chart 5-9.
Audio Response Test (X-Mode) at 500 Hz
11.
Turn AN/URM-127 FREQ RANGE DIAL to 50.
12.
Disconnect rf cable from Adapter UG-514. (See test setup diagram
.)
13.
Connect rf cable to AN/USM-207 FREQ A connector.
14.
Adjust AN/URM-127 FREQ RANGE DIAL for 500-Hz display on ANWSM-207.
15.
Disconnect rf cable from AN/USM-207 FREQ A connector.
16.
Reconnect rf cable to Adapter UG-514. Note ME-30(*)/U meter indication.
STANDARD. ME-30(*)/U meter should indicate between + 2db and -3 db of reading noted in
step 9.
17. If ME-30(*)/U meter does not indicate between + 2db and -3 db of reading taken in step 9, see
troubleshooting chart 5-9.
Audio Response Test (X-Mode) at 3 kHz
18.
Turn AN/URM-127 FREQ RANGE MULTIPLIER to x100.
19.
Turn FREQ RANGE DIAL to 30.
20.
Disconnect rf cable from Adapter UG-514. (See test setup diagram
.)
21.
Connect rf cable to AN/USM-207 FREQ A connector.
22.
Adjust AN/URM-127 FREQ RANGE DIAL for 3-kHz display on AN/USM-207.
23.
Disconnect rf cable from AN/USM-207 FREQ A connector.
24.
Reconnect rf cable to Adapter UG-514.
5-28


Privacy Statement - Press Release - Copyright Information. - Contact Us