5-9.
RECEIVER AUDIO RESPONSE TEST (X- MODE). (CONT)
CONTROL AND SWITCH SETTINGS
CONTROL OR SWITCH
POSITION/SETTING
EQUIPMENT
FREQUENCY TUNING-MC
AN/USM-207
100
POWER
TRACK
DISPLAY
MIN (fully counterclockwise)
INPUT
0.3 V MAX (both switches to left)
103 (black knob)
GATE TIME
SENSITIVITY
PLUG IN
FUNCTION
FREQ
DIRECT/HETERODYNE
DIRECT
OPERATE/OFF/STAND BY
AN/URM-103
OPERATE
BAND SWITCH
RF TUNING
64.00
DEVIATION RANGE KHZ
10
FUNCTION
EXT MOD
DEVIATION
Adjust for 8-kHz meter reading
RF SET TO LINE
To red line
RF OUTPUT
LO, 0-10 KUV
LO RF UV
20 v
FREQ RANGE MULTIPLIER
x10
AN/URM-127
FREQ RANGE DIAL
100
ATTENUATOR
x1
Fully clockwise (maximum)
OUTPUT CONTROL
RANGE selector switch
3V
ME-30(*)/u
BAND
R-442/VRC
MC-TUNE-KC
64.00
SQUELCH
OLD OFF
LIGHT
ON
VOLUME
Fully counterclockwise
POWER
ON
TEST PROCEDURE
1. Adjust AN/URM-103 RF TUNING control for 64.00-MHz display on AN/USM-207.
NOTE
To produce a display on the AN/USM-207, the AN/URM-103 rf level must be increased
by turning the LO RF UV control clockwise. When the display appears, readjust the
AN/URM-103 RF TUNING control until the AN/USM-207 indicates 64.00 MHz, and
reset the LO RF UV control to 20 v.
5-27