| TM 11-5820-401-34-3/0967-LP-432-3060
RECEIVER AUDIO RESPONSE TEST (X-MODE). (CONT)
5-9.
STANDARD. ME-30('WJ meter should indicate between + 2 db and -3 db of reading noted in
step 9.
25. If ME-30(*)/U meter does not indicate between + 2 db and -3 db of reading noted in
step 9, see troubleshooting chart 5-9.
Audio Response Test (X-Mode) at 5 kHz
26.
Turn AN/URM-127 FREQ RANGE DIAL to 50.
27.
Disconnect rf cable from Adapter UG-514. (See test setup diagram
.)
28.
Connect rf cable to AN/USM-207 FREQ A connector.
29.
Adjust AN/URM-127 FREQ RANGE DIAL for 5-kHz display on AN/USM-207.
30.
Disconnect rf cable from AN/USM-207 FREQ A connector.
31.
Reconnect rf cable to Adapter UG-514.
STANDARD. ME-30(*)/U meter should indicate between + 2 db and -3 db of reading noted in
step 9.
32. If ME-30(*)/U meter does not indicate between + 2 db and -3 db of reading noted in
step 9, see troubleshooting chart 5-9.
Audio Response Test (X-Mode) at 10 kHz
33.
Turn FREQ RANGE DIAL to 100.
34.
Disconnect rf cable from Adapter UG-514. (See test setup diagram
.)
35.
Connect rf cable to AN/USM-207 FREQ A connector.
36.
Adjust AN/URM-127 FREQ RANGE DIAL for 10-kHz display on AN/USM-207.
37.
Disconnect rf cable from AN/USM-207 FREQ A connector.
38.
Reconnect rf cable to Adapter UG-514.
STANDARD. ME-30(*)/U meter should indicate between + 2 db and -3 db of reading noted in
step 9.
39. If ME-30(*)/U r@er does not indicate between + 2 db and -3 db of reading taken in
step 9, see troubleshooting chart 5-9.
NOTE
Before performing any other test in this section, see R-442/VRC X-MODE SETUP
PROCEDURE (page 5-25) and do the following:
Set X-MODE-NORMAL Switch S4001 to NORMAL.
Return Filter FL4002 to its original position.