| TM 11-5820-401-34-3/0967- LP-432-3060
5-8. RECEIVER AUDIO RESPONSE TEST(NORMAL MODE). (CONT)
CONTROL AND SWITCH SETTINGS (CONT)
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
RANGE selector switch
30 v
ME-30(*)/U
OPERATE
OPERATE/OFF/STAND BY
AN/URM-103
BAND SWITCH
RF TUNING
64.00
10
DEVIATION RANGE KHZ
FUNCTION
EXT MOD
Adjust for 8-kHz meter indication
DEVIATION
RF SET TO LINE
To red line
RF OUTPUT
LO, 0-10 KUV
20 v
LO RF UV
BAND
R-442/VRC
MC-TUNE-KC
64.00
OLD OFF
SQUELCH
ON
LIGHT
VOLUME
Fully counterclockwise
POWER
ON
FREQ RANGE MULTIPLIER
x10
AN/URM-127
FREQ RANGE DIAL
100
ATTENUATOR
x1
Fully clockwise (maximum)
OUTPUT CONTROL
TEST PROCEDURE
Adjust AN/URM-103 RF TUNING control for 64.00-MHz display on AN/USM-207.
1.
NOTE
To produce a display on the AN/USM-207, the AN/URM-103 rf level must be increased
by turning the LO RF UV control clockwise. When the display appears, readjust the
AN/URM-103 RF TUNING control until the AN/USM-207 indicates 64.00 MHz, and reset
the LO RF UV control to 20 v.
2.
Disconnect T-connectors from AN/USM-207,
5-23
|