| TM 11-5820-401-34-3/0967-LP-432-3060
5-8. RECEIVER AUDIO RESPONSE TEST (NORMAL MODE). (CONT)
.
TEST SETUP. Connect test equipment as shown in test setup diagram
Turn on test equipment. Allow at least 15 to 30 minutes for warmup.
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
tabie. If using alternate test equipment, adjust for 64.00 MHz, 20-v rf input level, 1-kHz modulation,
and 8-kHz frequency deviation.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
100
FREQUENCY TUNING-MC
AN/USM-207
TRACK
POWER
MIN (fuliy counterclockwise)
DiSPLAY
0.3 V MAX (both switches to ieft)
INPUT
103 (black knob)
GATE TIME
PLUG IN
SENSITIVITY
FREQ
FUNCTION
DIRECT
DIRECT/HETERODYNE
5-22
|