| nections or test indications that
may differ from those given in
the test procedures.
(2) Unless otherwise specified, all
tests are to be performed with
the RT-505/PRC-25 connected to
Battery, Dry BA-386/PRC-25.
(3) The electrical tests should be con-
ducted in a screen room. If avail-
I
able, use Inclosure, Electromag-
netic Shielding MX-1761/G or its
equivalent.
c. Test Equipment.
Dummy Antenna
a. Dummy Antenna. A special 50-ohm
20-db pad (dummy antenna) is required
to couple the output of Signal Generator
AN/URM-48 to the input of the RT-505/
PRC-25. Fabricate the special 50-ohm,
20-db dummy antenna as shown in figure
b. Test Cable No. 1. Fabricate test
cable No. 1 as illustrated in figure 41.
c. Test Cable No. 2. Fabricate test
cable No. 2 as illustrated in figure 41.
d. Additional Equipment.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |