| module A20.
Section II. THIRD ECHELON TROUBLESHOOTING
Caution: Do not attempt removal or replacement of parts before reading the instruc-
tions in paragraph 40.
37. Test Setup
505/PRC-25 for bench testing as follows:
Position or indication
Control
(1) R e m o v e Battery Box CY-2562/
B A N D SWITCH a -------
C or D
PRC-25 and Battery, Dry BA-386/
RF TUNING controls ---
45.00 or 64.00
PRC-25 (TM 11-5820-398-10 (para
25
DEVIATION RANGE
switch.
OPERATION switch ----
(2) Remove the receiver-transmitter
DEVIATION LEVEL
Adjust for 10 kc on
case (TM 11-5820-398-20 (para
control.
KILOCYCLES DEVIA-
TION meter.
Adjust for MICROVOLTS
RF SET TO LINE
(3) Be sure the POWER receptacle
control.
meter indication at RF
cover is on the POWER receptacle.
SET TO LINE.
The POWER receptacle cover con-
RF ATTENUATOR MI-
Adjust for 0.70 microvolt
CROVOLTS control.
on right-hand meter,
tains jumpers necessary for bat-
tery operation.
`The setting of the BAND SWITCH and the RF TUNING control
will be determined by the RT-505/PRC-25 operating frequency.
(4) Connect the BA-386/PRC-25 to the
battery plug on the RT-505/PRC-
(b) Connect the AN/URM-48 RF ca-
25.
ble to one end of the dummy an-
b. Test Equipment.
tenna.
(1) Receiver section.
(c) Connect the other end of the
(a) Use the AN/URM-48 to provide a
dummy antenna to the receiver-
test signal. Set the controls on the
transmitter ANT connector; use
AN/URM-48 as follows:
cord CG-530/U.
|