TB 9-2320-387-35-6
2-28. Fabricate ground strap (42) from 8-in. length of braided wire and two terminal lugs.
NOTE
Remove paint from vicinity of integrated rack mounting holes
before performing step 2-29. Apply antiseize compound as
required.
2-29. Attach integrated rack (16) to radio rack support plate (36) using two capscrews (39), two washers (40),
ground strap (42), two washers (40), and nuts (41).
41
39
40
40
36
41
40
~
42
40
39
16
39.
CAPSCREW B1821BH025C150N QTY. 2
40.
WASHER 2436161 QTY. 4
41.
LOCKNUT M45913/4-4CG8Z QTY. 2
42.
GROUND STRAP
BRAIDED WIRE AA59569F30T0375 QTY. A/R
TERMINAL LUG MS20659-141 QTY. 2
Figure 5-14.
5-14