Section VII. SINCGARS MOUNTING TRAY AND POWER AMP INSTALLATION
7-1. Install standard radio rack if necessary. (Refer to TM 9-2320-387-24.)
7-2. Remove paint from five mounting holes (4) on standard rack (7) and five mounting holes (3) on
bottom of mounting base (2).
7-3. Apply antiseize compound to five mounting holes (4) and five mounting holes (3).
7-4. Install mounting base (2) on standard rack (7) with five capscrews (1), ten lockwashers (6), and five
nuts (5).
2
1
6
1.
CAPSCREW B1821BH031F100N QTY. 5
2.
MOUNTING BASE MT-6352/VRC A3013367-1 QTY. 1
5.
NUT 9418892 QTY. 5
6.
LOCKWASHER MS45904-72 QTY. 10
3
7
6
4
4
5
Figure 5-17.
NOTE
Perform step 7-5 for AN/VRC-92F only.
7-5. Install power amp (8) in SINCGARS mount (2).
8
2