| TB 11-5820-890-10-3
Assemble and install the radio set, KY-57, and HYX-57 individually per
4.
Equipment
Setup/Operation.
applicable technical manuals. P e r f o r m P r e v e n t i v e M a i n t e n a n c e C h e c k s a n d S e r v i c e s ( P M C S ) a n d / o r
B u i l t - I n - T e s t (BIT) functions. Load all frequencies, hopsets, and variables into the radio set. Load required
COMSEC data into the KY-57 and connect equipment as described in the following paragraph.
5 . C a b l i n g I n s t r u c t i o n s . The following figure illustrates the typical configuration for the connection between
the radio set and the KY-57 with Wire Line Adapter, HYX-57.
Refer to figure 1 and perform the following cabling procedure:
q
C o n n e c t Cable Assembly CX-13072 to RADIO connector on KY-57 and the RADIO/KY connector
on the HYX-57.
q
W i t h field wire, WD-1, connect the two HYX-57 Wire Line Adapters using the two set's binding
posts marked "T R".
q
Connect a Wire Line Adapter Interconnect Cable (CX-13310) from the RXMT connector on the RT
to the RADIO/KY connector on the Wireline Adapter.
2
|