Switch  Settings  and  Initialization.
communication  parameters  for  interoperability.
Table 6-1. SINCGARS Radio Set
MODE
SWITCH SETTINGS
RT-1439
HYX-57
RT-1523
KY-57
CX-13310
ICOM
NON-ICOM
PWR-LO
SC, RXMT
P
SC-PT
SC, RXMT,
PT-SC
PT
2 - W I R E , 16K
PWR-LO
P
FH, RXMT
FH, RXMT
PT-FH
FH-PT
2 - W I R E , 16K
PT
PWR-LO
SC, RXMT
SC-CT
SC, RXMT,
C, TD
CT
PT
2 - W I R E , 16K
PWR-LO
FH-CT
FH, RXMT,
FH, RXMT
C, TD
CT
PT
2 - W I R E , 16K
P
PWR-LO/Hl
N/A
N/A
OW
OW
2 - W I R E , 16K
NOTES:
When using the SINCGARS Ground Combat Net Radio, ICOM, RT-1523 for the remote
operation, the COMSEC switch on the radio must be turned to the PT position.
HYX-57 Interconnect Cable CX-13310 has a control box with a control switch for
selecting the positions listed under CX-13310.
When using order wire ("OW"), the H-250 handset should be connected to the
RADIO/KY connector on the HYX-57 at the remote site.
The maximum allowable wireline distance between the HYX-57s used to remote the
radio system is 4 miles.
CAUTION
DO NOT USE THE HI POWER POSITION OF THE HYX-57s WHEN
REMOTING A RADIO SET.