| TM 32-5895-206-10
a. After receiver and df antenna have been tuned for
maximum signal, adjust RF or RF GAIN control of the receiver
for approximately a two-thirds full scale reading on receiver panel
meter. Adjust VOL control as needed to set headset sound
level.
b. Find null (antenna position for minimum signal) as
follows. Rotate antenna pedestal mast to give minimum signal in
headset and null meter. As minimum is approached, adjust RF
or RF GAIN control to increase the signal strength to a useable
level. Do not set gain control to AVC position.
c. Read bearing of null under antenna mast cursor on
azimuth scale. Notice that two nulls 'can be found for every
signal. Nulls are exactly opposite each other on azimuth scale.
Target transmitter lies in the direction of one of the nulls.
d. Find location of target transmitter by taking a second
reading at another site. Location of second site will depend on
many conditions, which include tactical situation, available
terrain, and distance to target transmitter. Bearing of reading at
second site should be different enough from bearing at first site
to allow accurate plotting. Generally, second site should be
located at least 1000 yards from first site and at an angle of 900
from target bearing taken at first site.
2-64
|