2-9 OPERATING PROCEDURES.  The operating procedures
are broken down into procedures for several component groups.
Use the procedures that apply to the components of your set.
NOTE
The receiver signal can be heard with the
headset connected through the recorder/
reproducer  and  the  recorder/reproducer
mode selector switch set to OFF.
a. HF  Radio  Receiver R-1218/UR  Signal  types are:
amplitude modulation (AM), single sideband (LSB and USB), and
continuous wave (CW).
(1) Check to see that the components are properly
connected as shown in figure 2-10 or 2-12. Check the control
settings.
(2) Select antenna which works best. Move antenna
as necessary for best reception.
(3) Set the FUNCTION switch to AM, LSB, or USB as
required.
(a) Tune in CW or modulated continuous wave
(MCW code) on LSB or USB.
(b) LSB or USB signals will sound garbled on
AM.