| TM 32-5895-206-10
battery condition of the components as indicated below. Replace
or install the batteries as needed. Battery life may vary widely,
depending on use conditions.
a. Radio Receiver R-1218/UR or R-1518/UR. Approximate
battery life: R-1218/UR, 12 operating hours; R-1518/UR, 8
operating hours. Set the POWER switch to INT. Set the
FUNCTION switch to AM. Depress the PWR CHK switch and
read the battery condition on the panel meter. If the meter reads
in the red (REPLACE) range, replace the batteries as follows:
(1) Set the FUNCTION switch to OFF. Remove rear
battery compartment cover as shown in figure 2-8.
(2) Remove discharged batteries.
Dispose of
discharged nonrechargeable BA-30 batteries. Save discharged
rechargeable batteries (not normally used).
WARNING
Battery leaks result in corrosive deposits that
may cause skin injury. Be extremely careful
not to contact deposits with bare hands. If
contacted, wash hands immediately. Do not
wipe eyes until hands are washed.