| TM
11-6625-924-14
6 - 6 . Replacement of Synchro Transmitter
(2) Connect a jumper lead between the stator
yellow and blue wires.
Replace the synchro by performing the procedures in a
and b below, then position and zero adjust it by per-
(3) Set up the multimeter for operation in the 100-
volt ac range.
forming the procedures in c below.
a. R e m o v a l
(4) Connect the multimeter between the blue sta-
tor wire and the red rotor wire.
(1) Loosen the set screw in the synchro transmit-
ter control (fig. FO-l).
(5) Set the INDICATOR TEST switch to TEST.
(6) Set the synchro transmitted control to 0.
(2) Open the cover and remove the clamps holding
the synchro in position.
(7) Loosen the clamps holding the synchro.
(8) Connect the power source output to the INPUT
(3) Disconnect the synchro wires from the test set
and remove the synchro.
binding posts on the test panel.
b. Installation.
(9) Turn on the power source and set the test
panel POWER switch to ON.
(1) Place the new synchro in position with its
shaft in the synchro transmitter control.
(10) Slowly turn the synchro (not shown) until the
minimum indication is obtained on the multimeter (ap-
(2) Install the clamps to hold the synchro (clamps
removed in a(2) above).
proximately 15 volts).
(3) Tighten the set screw in the synchro transmit-
(11) Tighten the clamps holding the synchro.
ter control (fig. FO-1).
(12) Set the POWER switch (fig. FO-1) to OFF.
(13) Disconnect the multimeter from the test
(4) Connect the synchro wires to the test set. Refer
to the schematic diagram for color code connections
panel and the jumper lead between the yellow and blue
stator wires.
c. Synchro Positioning.
(14) Adjust the synchro transmitter control (para
(1) Connect a jumper lead between the rotor and
stator black wires.
6-2
|