| TM 11-6625-847-12
Item
No.
Trouble symptom
Probable trouble
Checks and corrective measures
6
When INPUT CURRENT
a. Improper seating of input
a. Tighten power connector.
switch is presser, volt-
power connector.
age is read across IN-
b. Defective INPUT CURRENT
b. Higher category repair re-
PUT CURRENT LO
switch.
quired.
test point and ground.
c. Defective fuse---------------------------
4-24.
Driver, Discriminator, and Antenna Coupler Tray A5, T rouble Localization Chart
The chart below specifies the performance required to be sure that tray A4 is operational.
Step
Control setting and
Performance standard and
No.
Operation of test
operation of equipment
references
equipment
Note. The AN/PSM-4
is the only piece of test
equipment required for fol-
lowing tests
1
Remove tray AS from case
2 and secure it to test
Bet.
2
Insure +27-volt dc pri-
Set test set switches and con-
mary power is supplied
trols to setting listed in para-
to test set POWER con-
graph 3-10. Set tray A5
nector.
switches and controls to set-
tings listed in paragraph 3-15.
3
Set test set POWER switch to
Test set POWER indicator il-
ON, and rotate SERV SEL
luminates.
switch to STBY.
4
Set tray A5 POWER switch to
Tray A5 POWER, RELAY 1,
ON.
and DRIVER 200 VDC indi-
cators illuminate.
5
Rotate DRIVER BAND SEL
DRIVER 200 VDC indicator il-
control from 3.25 MC to 15.5
luminates when DRIVER
MC and 29.5 MC.
BAND SEL control is in a de-
tent setting; extinguishes when
rotating (para 4-25, item No.
2).
6
Connect AN/PCM-6 ac
Set DRIVER TEST SELECTOR
7 + 0.5 volts ac (para 4-25, item
test leads to DRIVER
switch to 1.
No. 3).
test points HI and LO
(located above RELAY
RELAY CONTROL
switch) .
7
Set DRIVER TEST SELECTOR
switch to 2. Adjust test set
DC VOLTAGE 200 control for
+200-volt de indication on
AN/PSM-6.
8
Set DRIVER TEST SELECTOR
+27 + 1 volts dc (Para 4-25,
switch to 4.
item No. 4).
9
Press RELAY 1 through 7 in-
Each RELAY indicator should
dicators.
light when pressed (para
10
Disconnect AN/PSM-6 ---------
Reset all switches and controls
Test set and tray A5 POWER
to positions listed in para-
indicators extinguish.
4-17
|