| S802 is placed at the 120V position, and
p o w e r cord plug P801 is connected to a
nominal 115-volt power source. Under
t h i s condition, the two primary windings
o f the power transformer are connected
in parallel, as shown in B, figure 40. Fuse
F 8 0 1 protects the equipment from over-
load. The secondary output of transformer
T 8 0 1 is filtered by capacitors C801 and
C 8 0 2 (A, fig. 40). The filtered nominal
115-volt output is available at front-panel
r e c e p t a c l e J801 for connection through
C a b l e Assembly, Power, Electrical CX-
6 6 8 0 / U to the main unit POWER recep-
tacle.
b . 240V Position of S802.
When the
available power source for the test set is
2 2 0 - 2 5 0 - v o l t s , 50-400-cps, the external
transformer f u n c t i o n s as a stepdown
transformer. Setting the 120V-240V switch
to the 240V position connects the two pri-
Figure 39. Cable Assembly, Special Purpose,
mary windings of power transformer T801
Electrical Brunched CX-6681/URM-85,
i n series, as shown in C, figure 40. The
schematic diagram.
i n p u t voltage is reduced by a two-to-one
r a d i o , a n d a nominal 115-volt output,
transformer is used to supply the test set
f i l t e r e d by capacitors C801 and C802,
with an isolated source of power 110-125 -
i s available at receptacle J801 for ener-
Volts , 5 0 - 4 0 0 - c p s when its front-panel
gizing the test set.
switch S801 is placed at the ON position,
Figure 40. Transformer, Power, Isolation and Step-Down TF-248/G, schematic diagram.