| Table 2-1. Controls and Indicators (cont)
Key
Control or Indicator
Function
8.
Frequency Display
Displays current operating frequency when READ
(6 seven-segment LED displays)
pushbutton is pressed.
9
LOAD
When pressed, stores frequency which is set by
(pushbutton switch)
the pushbutton frequency selector switches into
memory location that corresponds to position of
the 1 through 6, GD A, GD B function selector
switch.
10
Function Selector
(ten-position rotary switch)
MAN
Allows an alternate or random frequency to be
selected manually by the frequency selector
switches, for use other than those which are stored
in memory.
Allows selection of frequencies which are preset
1 through 6, GD A and GD B
and stored in memory.
Selects preset frequency at function selector
T2/R1
switch position 2 for transmitting and position 1 for
receiving.