| TM 11-5895-1141-34
Table 4-13. MODULE TEST SET, RECORDER-MONITOR MODULE TEST (Cont'd)
Step
Operation
Normal Indication
The meter should read -10 2 dBm.
b. Set HEADSET/SPEAKER select switch to
SPEAKER. Set the OUTPUT SELECT switch to
LOUDSPEAKER. Set METER SCALE to 3.5 v/
+10 dB. Turn LOUDSPEAKER VOLUME control
on volume control module front panel CCW
until meter reads 1.1 v. Turn the OUTPUT
SELECT switch back to MIXER AMPLIFIER and
the METER SCALE back to 0.35 v/-10 dB.
c. Return HEADSET/SPEAKER select switch
Meter reading should be less than -47 dBm.
to center position.
12
Set INPUT SELECT switch to TEL 1 and OUT-
PUT SELECT switch to OSCILLATOR. Set
600 Ω switch to IN, METER SCALE to 35 mv/
-30 dB and adjust OSCILLATOR LEVEL to
-30 dBm. Repeat step 8.
Meter reading should remain at -10 2 dBm.
13
Set INPUT SELECT switch to TEL 2.
14
Return all test set switches to the ini-
tial position specified in
paragraph 4-10.
4-39
|