Click here to make tpub.com your Home Page

Page Title: Table 4-13. MODULE TEST SET, RECORDER-MONITOR MODULE TEST (Cont'd)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5895-1141-34
Table 4-13. MODULE TEST SET, RECORDER-MONITOR MODULE TEST (Cont'd)
Step
Operation
Normal Indication
Set 600DUMMY LOAD switch to OUT, METER
The meter should indicate -10 2 dBm.
8
SCALE to 0.35 v/-10 dB and OUTPUT SELECT
switch to MIXER AMPLIFIER.
9
Return LOCK/NONLOCK switch and P/T switch
to the OFF position. Set INPUT SELECT
switch to RCVR-AUDIO and the OUTPUT SELECT
switch to OSCILLATOR.
Set 600DUMMY LOAD switch to IN, METER
10
SCALE to 0.11 v/-20 dB and adjust OSCILLA-
TOR LEVEL for -20 dBm. Set both volume
controls on the front panel of the volume
control module fully CW.
Set 600 Ωn DUMMY LOAD switch to OUT, METER
11
SCALE to 0.35 v/-10 dB and OUTPUT SELECT
switch to MIXER AMPLIFIER.
The meter should read -10 2 dBm.
a. Set the HEADSET/SPEAKER switch on the
selector module to HEADSET.
4-38