| TM 11-5895-1141-34
Table 4-13. MODULE TEST SET, RECORDER-MONITOR MODULE TEST (Cont'd)
Step
Operation
Normal Indication
Set 600 Ω DUMMY LOAD switch to OUT, METER
The meter should indicate -10 2 dBm.
8
SCALE to 0.35 v/-10 dB and OUTPUT SELECT
switch to MIXER AMPLIFIER.
9
Return LOCK/NONLOCK switch and P/T switch
to the OFF position. Set INPUT SELECT
switch to RCVR-AUDIO and the OUTPUT SELECT
switch to OSCILLATOR.
Set 600 Ω DUMMY LOAD switch to IN, METER
10
SCALE to 0.11 v/-20 dB and adjust OSCILLA-
TOR LEVEL for -20 dBm. Set both volume
controls on the front panel of the volume
control module fully CW.
Set 600 Ωn DUMMY LOAD switch to OUT, METER
11
SCALE to 0.35 v/-10 dB and OUTPUT SELECT
switch to MIXER AMPLIFIER.
The meter should read -10 2 dBm.
a. Set the HEADSET/SPEAKER switch on the
selector module to HEADSET.
4-38
|