Table 4-12. MODULE TEST SET, MICROPHONE AMPLIFIER/LAMP BRIGHTENER MODULE TEST (Cont'd)
Step
Operation
Normal Indication
b. If no amplifier regulation was
The meter reading should be at least +10 dBm.
desired, the jumper between E21 - E22 may
have been removed. If this is so, the
regulation level (R1218) should be rotated
fully clockwise. Flip the 20 dB ATTENUA-
TOR switch to OUT.
c. Regulating action other than the
extremes described above (5a, 5b) may be
required to suit a particular operating
environment. If so, adjustments should be
made in accordance with procedures estab-
lished by authorized personnel.
6
Press the XMTR LOAD switch.
Observe the meter reading. It should not
drop more than 3 dB.
7
The microphone input should be unchanged
The meter reading (sidetone signal) should be
-25 2 dBm.
(-55 dBm). Set the HEADSET VOLUME control
fully clockwise. Set the INPUT SELECT
switch to HEADSET and METER SCALE to
0.11 v/-20 dB.
The meter reading should be -10 2 dBm.
8
Set METER SCALE to 0.35 v/-10 dB and the
OUTPUT SELECT switch to MIXER ATIPL
9
Return all test set switching and controls
to the initial positions indicated in
paragraph 4-10.