Table 4-12. MODULE TEST SET, MICROPHONE AMPLIFIER/LAMP BRIGHTENER MODULE TEST
Step
Operation
Normal Indication
1
All module test set controls must be pre-
set according to the procedure in
paragraph 4-10.
2
Set METER SCALE to 35 mv/-30 dB. Adjust
OSCILLATOR LEVEL to -35 dBm.
3
Set 20 dB ATTENUATOR switch to IN. This
does not change meter reading signifi-
cantly, but the input signal at T1201 in
microphone amplifier is reduced to
-55 dBm. Set 600 Ω DUMMY LOAD to OUT.
4
Set METER SCALE to 1.1 v/O dB; OUTPUT
Observe the red and green lamps of the selec-
SELECT to XMTR AUDIO; LOCK/NONLOCK switch
tor module. They should come on brightly.
to LOCK; P/T KEY switch to ON.
Verify that they become dimmer as the LAMP
BRIGHTENER control of the associated selector
module is rotated counterclockwise, but still
glows distinctly even at the CCW limit.
5
a. If a high degree of amplifier regula-
The regulation level (R1218) adjust is posi-
tion is desired, the input level (R1202)
tioned for an output reading of between
and output level (R1230) adjustments
-5 dBm and 0 dBm, dependent on the installa-
should be at their maximum clockwise
tion and site requirements.
position.
If the meter reading increases by more than
3 dB, R1218 should be adjusted to reduce the
increase to no more than 3 dB.