| TM 11-5895-1141-34
Table 4-11. MODULE TEST SET CONTROLS AND INDICATORS (Cont'd)
Controls/indicators or
Function
Connector
PRESS FOR XMTR LOAD switch
When pressed, places the equivalent of
S6
23 installed selector modules as an
additional load upon the amplifier in
the microphone amplifier/lamp
brightener module.
600-Ω DUMMY LOAD switch
When positioned to IN, routes input
S10
signals to a 600 ohm resistor instead
of to the INPUT SELECT switch.
20-dB
ATTENUATOR switch S9 When positioned to IN, attenuates
input voltage by a factor of ten
(20 dB).
EXTERNAL/INTERNAL INPUT
In EXTERNAL position, the input test
switch S5
signals are provided by a source
connected to the EXT SIGNAL INPUT
terminals.
In INTERNAL position, the input test
signals are provided by the
oscillator circuit of the test set.
P/T KEY switch S7
With jack unit not connected for test,
this switch simulates keying of
selected channel by operator. With
jack unit connected for test, this
switch keys the transmitter and allows
only the signal appearing at the
instructor headset Jack of the Jack
unit to be transmitted.
4-10.
PROCEDURE FOR TESTING MODULES
This section includes tables detailing the procedure for using the MTS-2400 Test Set to test the following modules:
Microphone Amplifier/Lamp Brightener Module
Recorder-Monitor Module