| TM 11-5895-1141-34
Table 4-10. CROSSTALK TESTS, TRANSMITTING AND RECEIVING CIRCUITS (Cont'd)
Step
Operation
Normal Indication
9
Terminate the transmitting audio line pair
of the first channel with a 600 ohm 1%,
1/2 watt resistor. Connect an ac volt-
meter across the terminating resistor.
Set the channel select switch of first
channel to the LOCK position. Close the
P/T switch.
10
Measure the receive to transmit crosstalk
The crosstalk level should be at least 50 dB
level at the transmitter audio
below the normal transmit level as determined
termination.
in section II (Test and Adjustment of Equip-
ment) of chapter 3.
11
Repeat step 10 with each of the other
channels keyed in turn. Repeat the fore-
going tests with the received signal input
connected in turn to each of the used
channels.
4-24
|