Table 4-10. CROSSTALK TESTS, TRANSMITTING AND RECEIVING CIRCUITS (Cont'd)
Step
Operation
Normal Indication
c. Connect an ac voltmeter across the
50 ohm resistor.
d. Set the switch S1001 of the first
channel to the Headset position, leaving
the switches of the other channels in the
off position. Set all the channel select
switches to the off position.
7
Set the received signal source to a level
Record the voltage across the 50 ohm headset
of 310 mv which is equal to twice that
load resistor.
normally used, allowing for a 6 dB drop in
the terminating resistor.
8
Set the switch S1001 of the first channel
The crosstalk level at the headset output
to the off position. Set the switch S1001
should be 50 dB below the reading of step 7.
of each of the remaining channels, one at
a time, to the Headset position, measuring
the crosstalk level at the headset load
resistor. Do this for each channel in
turn, with the switch S1001 of all the
other channels set to off.