Click here to make tpub.com your Home Page

Page Title: Table 4-9. RECORDER/MONITOR CIRCUITS TEST PROCEDURES
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5895-1141-34
Table 4-9. RECORDER/MONITOR CIRCUITS TEST PROCEDURES
Step
Operation
Normal Indication
1
Repeat steps 1, 2, 3 of the transmit test
procedure.
An output reading of 10 2 dBm should be
2
Connect the mixer amplifier output test
circuit (fig. 4-9) to J104 of the audio
obtained across the 600 ohm load resistor.
unit.
3
Remove the test circuit and replace with
Turn the front panel lamp brightness control
the recorder-monitor test circuit
to maximum. The recorder monitor syllabic
(fig. 4-10). Apply a monitor input
lamp on the audio unit front panel should be
level of -30 dBm by setting the audio
barely visible. If not, adjust R1313, the
oscillator for an output of 49 millivolts
syllabic lamp threshold adjust to achieve
at a frequency of 1000 Hz.
this light level. See figure 4-11.
4
1 Increase the audio oscillator output to
The syllabic lamp should be at full
0.49 v for an input of -10 dBm.
brightness.
5
If the installation instructions call for
Adjust R1313 to achieve barely lighted condi-
a threshold setting other than the -30 dBm
tion of the syllabic lamp.
of step 3 above reset the signal level in
the test circuit.
This completes the recorder/monitor test.
Remove test circuit.