Click here to make tpub.com your Home Page

Page Title: Table 1-1. Tabulated Data
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5826-258-24
Table 1-1. Tabulated Data-Continued
When the DDM of a standard localizer signal is abruptly changed, the pointer of a
Localizer
CDI ID-1347C/ARN or equivalent shall reach 67% of its ultimate deflection
within 2 seconds and pointer overshoot shall not exceed 5%.
-46 C to +55 C.
Operating temperature
-54 C to +71 C.
Storage Temperature
Warmup time:
Less than 90 seconds
Standard temperature conditions
Less than 3 minutes.
Extreme temperature conditions
Power input:
Meets specified performance when operated from a dc primary source with
Performance
characteristics and limits as defined in MIL-STD-704 dated 6 October 1959,
Category B.
Meets transient conditions as specified in MIL-STD-704 dated 6 October 1959.
Power source transients
Mark 11 Standard Frequency Control System (2-out-of-5).
Frequency control
Better than 60 db.
spurious rejection
VOR and localizer
Standard outputs
Left-right deviation output capable of driving four 1000-ohm 150-0-150 micro-
ampere meter movements.
Warning signal output capable of driving three 1000-ohm 250 microampere meter
movements.
VOR only.
Ambiguity output capable of driving two 500-ohm, 200 microampere meter move-
ments.
Ambiguity indication will be clearly TO and FROM over the rf signal input range
of 10 to 20,000 microvolt and at all bearings up to 60 from the selected
radial.
100 millivolts minimum
Ambiguity sensitivity
GS receiver section
329.15 MHz through 335.00 MHz
Frequency range
40
Number of channels
150 kHz
Channel spacing
52 ohms
6:1 maximum
VSWR
Centering error less than 10 millivolts (Class D) under the conditions of paragraph
Accuracy
2.1 of RTCA Document DO-132.
78 millivolts for .091 DDM with a deflection linearity of 78 7.8 millivolts at
Deflection sensitivity
0.091 DDM.
Does not require more than 20 microvolt Standard GS Test Signal for fully con-
Rf sensitivity
cealed GS flag and satisfactory navigation performance.
When the DDM of a Standard Glide Slope Test Signal is abruptly changed from
Damping characteristics
zero to any value less than 0.175 DDM, the winter of a CDI ID- 1347C/ARN or
equivalent will reach 67% of its ultimate deflection within 2 seconds and
pointer overshoot will not exceed 5%.
-46 C to + 55 C.
Operating temperature
-54 C to + 71 C.
Storage temperatures
warmup time:
Less than 90 seconds
Standard temperature conditions
Less than 3 minutes
Extreme temperature conditions
Power input:
Meets specified performance when operated from a dc primary source with char-
Performance
acteristics and limits as defined in MIL-STD-704 dated 6 October 1959, Cate-
gory B.
Meets transient conditions as specified in MIL-STD-704 dated 6 October 1959.
Power source transients
Mark II Standard Frequency Control System, (2-out-of-5).
Frequency control
Better than 60 db.
Spurious rejection
Updown deviation output capable of driving three 1000-Ohm 150-0-150 micro-
Standard outputs
ampere meter movements.
MB receiver section:
75 MHz.
Operating frequency
52 ohms.
2:1 maximum
VSWR
More than 55 db attenuation at all frequencies outside the range of 74.8 MHz to
Selectivity
75.2 MHz.
Receiver threshold adjustment range
Adjustable from 200 to 1000 microvolt.
High sensitivity mode activated by providing a
Adjusted to 500 microvolt.
ground to receiver
1-6


Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business