TM 11-5821-333-12
3-3. LOADING FILL DEVICE FROM ANOTHER FILL DEVICE.
Fill Device Connected to
ACTION
a.
b.
c.
d.
e.
f.
9.
Set both fill device function switches to OFF.
Connect fill devices together. Two methods
are shown in above figures. A fill cable does
not have to be used but is preferred. The fill
devices may be connected directly from con-
nector J1 to connector P1. (See illustrations. )
Set both fill device function switches to ON.
On fill device having data, set the select
switch to the position of desired fill data. If all
positions are to be transferred, set to A.
On fill device to be filled, set the select switch
to position to be filled. If all positions are to
be filled, set to A.
Watch CHECK lights on fill devices. On the fill
device to be filled, press the initiate switch.
Record data identification number on side
panel of fill device.
Fill Device
RESPONSE
3-2
|