11-5820-919-40-1
WARNING
Encapsulate  the  jumper  wire
as
5.
described in steps 6 thru 8.
Handling  hot  items  presents
a  serious  injury  potential.
WARNING
Asbestos  gloves  are  required.
Adhesives  are  irritating  to  the
skin and eyes upon contact, and
10.
Allow the adhesive to gel for a
may  emit  harmful  vapor.
Use
minimum  of  1  hour  at  room  temperature
only  with  adequate  ventilation..
and then bake for 1 hour minimum at a
Avoid all skin and eye contact.
10  OF, or allow
temperature of 150
Use  protective  clothing  such  as
adhesive  to  air  dry  at  room  temperature
rubber  gloves,  apron  and  eye
for  24  hours.  If  adhesive  is  oven
Wash  off  immedi-
protection.
cured, allow it to cool at room temper-
.
ately  any  accidentally  contami-
ature  after  removal  from  the  oven.
nated  skin  area.  Hand  washing
facilities  and  eye  wash  foun-
tain  should  be  provided.  Do
REPAIR  OF  BROKEN  THERMAL  MOUNTING
not  take  internally.
PLATE  POWER  OR  GROUND  TABS.
Broken
thermal  mounting  plate  power  or  ground
tabs  may  be  repaired  using  copper  jumper
Use any one of the Narmco Epoxy
6.
wire by performing `the following steps:
Adhesive  Kits  No.  3135  listed  in  table
If the frozen premix kit is used,
3-2.
Technical  personnel  familiar  with
1.
allow it to thaw to room temperature
the  function  of  the  circuit  must  deter-
prior to use.
If either of the two-part
mine the two points to which the copper
kits  is  used,  mix  small,  approximately
jumper wire is to be attached.
equal, quantities of Part A and Part B,
using  a  disposable  aluminum  cup  for
mixing.  Mix  thoroughly.
Form  the  26-gage  insulated  copper
2.
jumper  wire  to  the  designated  points  and
Bond the jumper by applying a
7.
cut to the required length (fig 3-9).
uniform  coat  of  adhesive  over  the  entire
length  of  the  jumper  wire.  Do  not  use
Strip a distance of 1/4 to
3.
more  adhesive  than  necessary  to  com-
5/16 inch from the wire ends.
pletely  cover  the  jumper  wire.
CAUTION
WARNING
Handling  hot  items  presents  a
The areas to be soldered must
serious  injury  potential.
be  heated  until  the  solder
Asbestos  gloves  are  required.
flows.  Overheating  can  dam-
age  the  board  or  nearby  com-
ponents.  The  wires  being
8.  Allow  the  adhesive  to  gel  for
soldered  must  not  be  allowed
1 hour minimum at room temperature and
to move in relation to one
then bake for 1 hour minimum at tem-
another  until  the  solder  has
perature of 150
10 *F or allow adhesive
completely  solidified.
to air dry at room temperature for
24  hours  minimum.  If  adhesive  is  oven
cured, allow it to cool at room temper-
Solder each end of the jumper wire
4.
ature  after  removal  from  the  oven.
to  the  selected  pads.