| TM 11-5820-918-13
MAINTENANCE
5-1. INTRODUCTION
5-2. This section provides maintenance and service information for the TCS-4B trans-
mitter. Included are tables of recommended test equipment, a preventive maintenance
schedule, corrective maintenance procedures, and performance verification data. An
understanding of the theory of operation from Section 4 is required for troubleshoot-
ing and repairing the equipment.
TEST EQUIPMENT
5-4. Recommended test equipment for performance tests and troubleshooting is listed
in table 5-1. Other test instruments may be used if their performance is equivalent
to those listed. If a test measurement is made which is outside the acceptable range,
operation of the test equipment should first be verified before assuming malfunction
of the equipment under test.
Test Equipment Required
Item
Recommended manufacturer and type
Tektronix 455 (or 465)
Frequency Counter
Hewlett Packard 5300B
Simpson 460
Termination, 2 watts
Microlab FXR TA - 5MN
Attenuator, 20 dB
Tektronix 011-0059-02
Bird Electronic Corp. 6155
RF Wattmeter
Hewlett Packard 141T
Spectrum Analyzer
with IF Section
Hewlett Packard 8552B
RF Section
Hewlett Packard 8553B
Power Supply
Lambda LL-903-0V, or
(35VDC Lab type)
Lambda LP-522-FM, or
HP 6200B
PREVENTIVE
MAINTENANCE
5-6. Table 5-2 provides a list of recommended preventive maintenance procedures.
To assist in obtaining long-term trouble-free operation of the transmitter, the pro-
cedures should be adhered to as closely as possible. Marginal operation of any unit
checked should be noted and carefully re-examined at the next maintenance period.
|