(8) Turn off BAT switch.
(9) Secure equipment for shipping or storage.
CAUTION
Do not turn on AC line power to instrument at any time after the batteries
are disconnected with battery box cutout pushbutton until equipment
is ready for normal use.  Applying AC line power to unit automatically
reconnects batteries to battery charger circuit (even with front panel
BAT switch off) and slowly discharges batteries when AC line power
is removed.  If AC line power is accidentally applied prior to storage,
repeat procedure starting at step 2 above.
3-16. For long term storage (more than six months) of transmitters with the non-
rechargeable standby battery supply, remove and store separately the D-cell bat -
teries.  For transmitters with the rechargeable battery supply, first, perform the
procedure of paragraph 3-15, b above, then remove the complete battery drawer
assembly from the 1024 and store separately to avoid damage from any possible battery
cell leakage.
NOTE
Early versions of the rechargeable battery supply - part number 6025-
1018, Revision A - did not include a battery cutout pushbutton switch
(S1). Later versions - Revision B and on - include the cutout switch
(S1) and a deep-discharge battery protection circuit that prevents bat-
tery damage if the battery supply is accidentally left on and allowed to
discharge.  The Revision A version of the battery supply may suffer
permanent damage, and can not be recharged, if it is allowed to com-
pletely discharge or if it is stored for long periods without first being
fully charged.  Operating procedures for the Revision A version of the
rechargeable battery supply are the same as for the non-rechargeable
battery supply.  However, the Revision A rechargeable battery supply
should be stored only after it is fully charged. If difficulties or poor
performance are encountered with the Revision A battery supply, con-
tact BR Communications for assistance or repair.