TM 11-5820-890-30-5
18-7. OPERATIONAL CHECK. Continued
Step 2. LOADING FH DATA (LOCAL FILL) INTO RT (RECEIVER-TRANSMITTER).
Action
a.
b.
c.
d.
e.
f.
g.
h.
i.
Prepare RT for operation.
Set fill device FUNCTION switch to OFF
position.
Connect fill device connector J1 to RT
AUD/FILL connector using fill cable, as
shown in figure 18-2.
Set RT FCTN switch to LD,
set MODE switch to FH, and
set CHAN switch to position where
FH data is to be loaded.
Set fill device FUNCTION switch to ON, and
set SELECT switch to position containing
FH data.
Press LOAD key and then STO key on RT
keypad.
Press number button of channel in which
data is to be stored.
Set fill device FUNCTION switch to OFF,
and disconnect fill device and fill cable
from RT.
Operational Check is complete.
Response
a.
b.
c.
d.
e.
f.
g.
h.
Make sure that the fill device is loaded.
If the fill device needs to be filled, see
Step 1 on page 17-3.
No response.
No response.
No response.
No response.
RT display will cycle as shown, and a
beep is heard.
RT display blinks and STO is shown,
followed by the channel number in
which the data was stored.
No response.
18-5
|