18-7. OPERATIONAL CHECK. Continued
Step 1. LOADING FILL DEVICE FROM ANOTHER FILL DEVICE.
Action
Response
a. Set both fill device FUNCTION switches
to OFF.
b. Connect both fill devices together. Two
methods are shown in figure 18-1. A
fill cable does not have to be used but
is preferred. The fill devices may be
directly connected from connector J1 to
connector P1. (See illustrations.)
c. Set both fill device FUNCTION switches
to ON.
d. On fill device having data, set the SELECT
switch to the position of the desired fill
data. If all positions are to be transferred,
set to A.
e. On fill device to be filled, set the SELECT
switch to position to be filled. If all positions
are to be filled, set to A.
f. Watch CHECK lights on fill devices. On the
fill device to be filled, press the INITIATE
switch.
g. Record data identification number on side
panel of fill device that has been filled.
h. Repeat steps d thru g for each position to
be filled.
i. Set fill device FUNCTION switch to OFF and
disconnect fill devices.
a. No response.
b. No response.
c. No response.
d. No response.
e. No response.
f. The CHECK lights blink when data is
transferred.
g. No response.
h. See responses for steps d thru g.
i. No response.
18-3
|