14-21. REPLACEMENT OF J3 OR J4 CONNECTOR. Continued
ITEM
ACTION
REMARKS
INSTALLATION
h.
Connector (4) or (8)
and Iockwasher
i.
O-ring
j. Hex nut and
Iockwasher
k.
Connector (4) or (8)
wires
l.
Rear access cover (2)
m. 12 captive
screws (3)
n.
Protective cap (5)
Obtain replacement connector and
Iockwasher.
Apply silicone compound to o-ring
on replacement connector.
Use 7/8 inch socket wrench.
Install and hand tighten retained
hex nut and replacement Iockwasher
securing the connector to the access
cover. Use torque wrench and 7/8 inch
socket. Torque to 60 in-lb.
Use soldering kit, soldering aid, and
Before and after soldering,
heat sink. Solder tagged wires to
clean wires and connector
correct connector pins, and remove
pins with alcohol and
wire tags.
cotton swabs.
Position retained rear access cover on
the power supply adapter chassis.
Use flat tip screwdriver. Install and hand
tighten the 12 captive screws securing
the rear access cover to the power supply
adapter chassis. Use torque screwdriver.
Torque to 9 in-lb.
Install the protective cap on the
connector.