TM 11-5820-890-30-5
2-34. REPAIR PROCEDURES. Continued
a.
General Instructions. Continued
5.
Handle all modules carefully.
6.
Before installing a module, check the connector for bent or broken pins. Do not install if damaged.
7.
Perform the operational check.
b.
Repair Precautions.
Static electricity
CAUTION
can damage the RT modules. Ground the RT and all tools before removing a
module. Use a grounded wrist strap when handling a module.
Steps marked with must be performed exactly as written. They are critical in maintaining
the nuclear hardness of the RT. Seals must not be damaged. All screws must be torqued to the
limits specified in the replacement procedures.
2-35. REPLACEMENT OF RT COVERS.
a.
Removal and Installation of Top Cover.
Tools:
Flat tip screwdriver
Torque screwdriver
ITEM
ACTION
REMARKS
REMOVAL
a.
RT
Set on work surface with top side up.
b. 11 captive screws
Use flat tip screwdriver. Fully loosen.
c. Top cover
Lift free from RT.
INSTALLATION
d. Top cover
Set in place on RT.
e. 11 captive
Thread and tighten. Use torque screw-
screws
driver. Torque screws to 8 to 10 in-lb.
2-159
|