TM 11-5820-890-20-2
2-5
2.1.
OPERATIONAL CHECK. Continued
STEP 4. VAA REMOTE DC POWER CHECK: Continued
STEPS TO PERFORM
CHECKS TO MAKE
ACTIONS TO TAKE
4.11 Set AM 1780 MAIN PWR to INT ONLY
N/A
Go to Step 4.12
4.12 Set RT-A LS 671 CB1 to ON
RT A LS 671 CB1 trips?
NO:
Go to Step 4.13
YES: Replace LS 671
4.13 Set RT-A FCTN to LD and back to SQ ON
RT-A display lights?
YES: Continue
NO:
Go to TS Chart 15
RT-A LS 671 DS1 lit?
YES: Go to Step 4.14
NO:
Go to TS Chart 16
4.14 Set RT-A LS-671 CB1 to OFF.
Set RT-B LS-671 CB1 to ON.
RT B LS 671 CB1 trips?
NO:
Go to Step 4.15
YES: Replace LS 671
4.15 Set RT-A FCTN to LD and back to SQ ON
RT-A display lights?
YES: Continue
NO:
Go to TS Chart 19
RT-B LS 671 DS1 lit?
YES: Go to STEP 6
NO:
Go to TS Chart 16
STEP 5. SRM REMOTE DC POWER CHECK:
STEPS TO PERFORM
CHECKS TO MAKE
ACTIONS TO TAKE
5.1
Set PSA CB1 to ON
PSA DS1 lights?
NO:
Go to Step 5.2
YES: Go to TS Chart 20
5.2
Set AM 1780 MAIN PWR to NORM
PSA CB1 trips?
NO:
Continue
YES: Go to TS Chart 21
PSA DS1 lights?
YES: Continue
NO:
Go to TS Chart 22
AM 1780 DS501 lights?
YES: Go to STEP 7
NO:
Go to TS Chart 23
|