0.2.
ASSOCIATED EQUIPMENT
SCOPE
This paragraph of your SINCGARS Operator's Manual briefly
addresses the maintenance requirements of those items of equipment
most often used in conjunction with your radio. The intent of this
paragraph is to give you a summary of operator maintenance tasks and
provide appropriate references from which more detailed information
may be obtained.
8.2a.
PMCS for Control, Receiver-Transmitter (RCU)
DIFFERENCES
Major differences between the SINCGARS RT and RCU are these:
RCU does not accept FH data; uses that data loaded into the
companion RT
RCU has speaker connection and switch in lieu of RT RXMT and
ANT connectors.
RCU FCTN switch has an intercom (ICM) position in lieu of the RT
remote (REM) position.
RCU SIG display lights when companion RT receives a signal.
RCU [BATT] key on first press provides RCU battery life Indication,
on second press provides RT battery life indication.
If two-wire connecting RCU with RT is cut or disconnected (or RT
FCTN is not set to REM), RCU display shows "OPEN."