| TM 11-5820-890-10-8
6.3i.
Conduct Cold Start Net Opening (Primary NCS Task 4)
DESCRIPTION
The Cold Start net opening procedure has for most units been replaced
by the simpler, less demanding, Hot Start method covered in Primary
NCS Task 3, above. The Cold Start method remains an option for NCSs
to use if desired. The Cold Start net opening procedure requires
operators to load their radios with COMSEC keys and FH data, but not
sync time. Sync time is passed electronically from the NCS to net
members by ERF. Coordination is essential to ensure that all operators
are ready when the ERF is sent and that they properly store the data.
While the Cold Start method works, experience has shown that
coordination requirements and operator actions make it a more
demanding process than the Hot Start method. It is available for use
whenever an NCS needs to bring all operators into the net at the exact
same time.
DETAILED FLOWCHART
CONDUCT COLD START NET OPENING
SUBTASKS
ACTIONS
RESULTS
a. Prepare NCS radio for
Load CUE, MAN and SC
(7)
(Perform Primary Operator Task 1)
Cold Start net opening
freqs, as required
Load COMSEC keys, FH
(2)
(Perform Primary Operator Task 2)
data, and sync time*
Prepare net operators for
b.
Ensure all operator RTs
(1)
(Operators perform an ICOM fill
Cold Start net opening
are properly loaded
less sync time)
(2) Advise operators when
(Operators must be standing by
the net is to be opened
at exact net opening time)
c. Send ERF at announced
(1)
Alert net that ERF is to be
(Helps operators note when ERF
net opening time
sent at this time**
is received)
(2)
Press [LOAD] on RT
RT display shows "HLD"
(Get data from what chan?)
Enter channel in which
(3)
RT display shows "HF XXX,"
ERF data is stored
blinks and beeps
Press [ERF] on RT
(4)
RT display shows "SEND"
6-15
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |