| TM
11-5820-890-10-8
Perform Hot Start Net Opening (Primary Operator Task 3)
5.4f.
This task is required when the net has been down for any reason and is
DESCRIPTION
now to become operational at a prescribed time. This procedure may
also be used when an individual operator has been out of the net for
any reason and wishes to re-enter the net without resort to the CUE
and ERF method of late net entry. This task involves two basic steps:
loading the radio with COMSEC keys, FH data, and sync time by use of
the ICOM fill procedure (Primary Operator Task 2); and calling the NCS
in secure, frequency hopping mode to request net entry.
DETAILED FLOWCHART
PERFORM HOT START NET OPENING
RESULTS
ACTIONS
SUBTASKS
(1) Perform ICOM Fill
RT channels (6) are loaded with
a. Load RT with COMSEC/
(Primary Opr Task 2)
COMSEC/FH/sync time
FH data/sync time
(2)
Load sync time manually
N/A
if required by RT version*
Call NCS using CT FH
N/A (NCS responds)
b. Enter net
(1)
mode
(2)
Request permission to
Hot Start net opening is
completed for this operator
enter the net
*
If the message "RT cannot accept time from ANCD" appears, go to subtasks c and d below
to manually load Julian Date and sync time. Once that has been accomplished, contact your NCS
and enter the net.