PRIMARY TASK 4:
Perform Passive Late Net Entry
Required when an operator's radio sync time becomes greater than
plus or minus 4 seconds, but not more than one minute, different from
net sync time. The Passive Late Net Entry process enables an operator
to re-enter the net without requiring action on the part of the NCS or
other net operators.
PRIMARY TASK 5:
Obtain SOI information from ANCD
SOI information electronically stored in the ANCD replaces the paper
SOI extract. The ANCD SOI program is used when Information on nets,
suffixes, pyro/smoke, sign/countersign is needed. It may be used to
view quick reference (QREF) related items in group, time period, set,
find, and memo. It may also be used to obtain the net ID of a net that is
not a part of the loadset being used.
5.4c. Select RT Preparation Settings from MENU (Preparation TASK 1)
DESCRIPTION
This task is required to set the ASIP radio to proper settings for other
tasks. MENU selections are Volume, Channel, Power, Mode and
COMSEC. These settings will need to change as operationally
necessary. The backlight function is also covered.
DETAILED FLOWCHART
SELECT RT PREPARATION SETTINGS FROM MENU
ACTIONS
RESULTS
SUBTASKS
Press MENU to display Vol level
a. Set RT Volume
(1) Press MENU
Display reads WHSP if 0 selected
(2)  Press Digit (1 -9) for Vol
Setting (0) for Whisper Mode
Display reads (1-6), (Q) for CUE,
b. Set RT Channel
(1)
Press MENU (until CHAN)
(2)
Press Digit (1-6) for Channel
(M) for Manual
desired (0) for MAN (7) for
CUE
(1)
Press MENU (until PWR)
Display reads (LO, M, HI, PA)
c. Set RT Power
(2)
Press CHG for desired PWR
setting
Display reads (SC, FH, FHM)
(1)
Press MENU (until MODE)
d. Set RT Mode
(2)
Press CHG for desired
MODE
Display reads (PT, CT, TD, RV)
(1)
Press MENU (until CMSC)
e. Set COMSEC
(2)
Press CHG for desired
CMSC setting
Backlight lights (4 settings Low to
(1)  Place RT on SQ ON
f. Set Backlight
High, then OFF)
(2) Press FREQ/Backlight
(3)
Press CHG until desired
setting
Default Settings are: VOL (5), CHAN (1), PWR (LO), MODE (FH), COMSEC (CT}