Figure 5-14. ASIP RT FUNCTION SWITCH
FUNCTION CONTROL POSITIONS AND USES
PURPOSE
POSITION
OFF
All power is shut off; all stored data, (COMSEC, FH, sync time, and manpack
battery life indicator) are deleted after 5 seconds; radio is completely
inoperable; position is used when radio is not in use and for storage.
Clears COMSEC, after 5 seconds clears all FH data; operator pauses in this
(Zero)
position for 5 seconds when setting FCTN switch to OFF.
STBY
Makes radio inoperative but all stored data is retained; sync time is lost after
200 hours; setting FCTN to SQ ON returns radio to fully operational status. In
(Stand By)
STBY, power is drawn from main source.
TST
This position causes self-test of RT data and ECCM circuits; test results are
shown in RT display. Running RT self-test is a routine step in start up
(Test)
procedure.
LD
The load position is required for loading SC frequencies, FH data, and
(Load)
COMSEC keys; required also to receive an ERE
SQ ON
This is the normal operating position of the radio for FH mode. For SC mode,
this position reduces noise.
(Squelch On)
SQ OFF
This position is not used for the FH mode. In the SC mode, SQ OFF helps to
bring distant stations, to work through jamming, and to be compatible with
(Squelch Off))
radios lacking squelch capability.
REM
The REM position disables front panel controls and is required for use of the
Control-Monitor, Remote Control Unit (RCU) and HRCRD.
(Remote)
RXMT
Use of the RXMT position enables the RT to automatically retransmit traffic from
one radio through another. Both RTs are set to RXMT position and connected
(Retransmit)
by an RXMT cable.