| TO 31R2-2GRC171-2
TM 11-5820-815-14
NAVELEX 0967-LP-544-5010
Table 5-3. Radio Receiver-Transmitter RT-980/GRC-171 Performance Tests (Sheet 17 of 17)
CONTROL SETTINGS
OPERATION OF TEST
AND OPERATION
PERFORMANCE
STEP
EQUIPMENT
POINT OF TEST
OF EQUIPMENT
STANDARD
RADIO RECEIVER-TRANSMITTER OPERATIONAL PERFORMANCE (Cont)
73
PLL OUT
PLL OUT
0.5 to 1.5 V dc.
(Cont)
(A10A1TP4)
PLL FAULT
PLL FAULT
2.0 to 5.0 V dc.
(A10A1TP5)
PA FWD
PA FWD
0.5 to 1.2 V dc.
(A10A1TP6)
PA REFL
PA RE FL
-0.3 to 0.3 V dc.
(A10A1TP7)
ALC
ALC
0.5 to 2.5 V dc.
(A10A1TP8)
KEY
KEY
0.05 to 0.5 V dc.
(A10A1TP9)
XMT AUDIO
XMIT AUDIO
Whistle or hum into
0.6 to 1.1 V rms.
(A10A1TP11)
microphone.
RECT DC
RECT DC
21 to 60 V dc.
(A10A1TP13)
74
Connect vom between
SERVO +
SERVO+ and SERVO-
SERVO + and GND and
(A10A1TP1)
to ground (in quiescent
SERVO - and GND test
state) 0 to 6.5 V dc.
points on the
GND
RT-980/GRC-171.
(A10A1TP14)
SERVO -
(A10A1TP2)
75
Connect digital multi-
Unkey transmitter.
meter to the following
RT-980/GRC-171 test
points and verify
readings:
RCV AUDIO
RCV AUDIO
0.16 to 0.3 V rms.
(A10A1TP10)
IF AGC
IF AGC
-0.3 to -0.7 V dc.
(A10A1TP12)
76
Turn off and disconnect
Place Radio Set
all test equipment from
AN/GRC-171 in
RT-980/GRC-171.
operational status
required.
5-23
|