| TO 31R2-2GRC171-2
TM 11-5820-815-14
NAVELEX 0967-LP-544-5010
Table 5-3. Radio Receiver-Transmitter RT-980/GRC-171 Performance Tests (Sheet 16 of 17)
CONTROL SETTINGS
OPERATION OF TEST
AND OPERATION
PERFORMANCE
STEP
EQUIPMENT
POINT OF TEST
OF EQUIPMENT
STANDARD
TRANSMITTER KEYING (Cont)
70
Disconnect audio
oscillator from
RT-980/GRC-171.
RADIO RECEIVER-TRANSMITTER OPERATIONAL PERFORMANCE
71
Connect RT-980/GRC-
Set RT-980/GRC-171
171, C-7999/GRC-171,
switches as follows:
and antenna as for nor-
REMOTE/LOCAL
mal operation. Connect
to LOCAL,
Handset H-169U to
SQUELCH to ON,
RT-980/GRC-171
PTT/CARRIER TEST
DYNAMIC MIC jack.
to PTT, TEST
meter selector to
OFF, POWER to ON,
and frequency selec-
tor to an authorized
assigned frequency.
72
TEST meter
Key transmitter and
(A10A1M1)
rotate the TEST
meter selector
through the follow-
ing settings and
verify readings:
FWD PWR
16 to 24 watts.
RFLD PWR
Not more than 25%, of
forward power.
% MOD (talk into
Observe needle
handset micro-
movement.
phone on this
setting)
TEMP
Meter does not read
in OVER TEMP range.
+26V
26 + 1.5 V dc.
+22V
22 + 1.5 V dc.
+12V
12 + 1.0 V dc.
+5V
5.1 + 0.5 V dc.
-12V
12 1.0 V dc.
73
Connect digital multi-
Key transmitter.
meter to the following
RT-980/GRC-171 front
panel test points and
verify readings:
TUNE VOLT
TUNE VOLT
-0.54 to -0.60 V dc
(Cont)
(A10A1TP3)
(300.000 MHz).
5-22
|